『oxygen flow meter China|digital flow meter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. High score calculation of several physical and chemical instruments in both Chinese and English
Dissolved oxygen analyzer technical parameters display: Chinese display, 192 × 64 dot matrix LCD range: 0-20ug/L; 0~200ug/L; 0-20mg/L (automatic shift) resolution: 0.1 ug/L; 0.01 mg/L; Accuracy:<± 3% F.S or 1ug/L (whichever is greater) Reading response time: 90% change within 60 seconds at 25 ℃ Temperature sensor: thermistor Temperature measurement range: 0.0~99.9 ℃ Temperature measurement accuracy: ± 0.5 ℃ Temperature measurement resolution: 0.1 ℃ Temperature compensation range: 0~50 ℃ (manual or automatic) Sample conditions: Temperature range: 5~50 ℃ Flow range: 100~400ml/min (best around 250ml/min) Water sample allowable solid content: ≤ 5 microns (no gum or grease allowed) Environmental temperature: 5~45 ℃ Environmental humidity: ≤ 90% RH (no condensation) Output current: 0~
10, 0~20 or 4~20mA (two-way isolated output) Output current accuracy: ± 0.1mA Maximum load resistance: 800 Ω (20mA Max.) Voltage: 198VAC~242VAC, 50Hz ± 1Hz Power: ≤ 8VA Insulation: Power supply to ground 1500V/1 Minute no arcing alarm output: dual normally open programmable relay contacts: 5A/30VDC or 5A250VAC. Communication: CAN bus (optional) Storage and transportation temperature: -25 ℃~55 ℃ (excluding electrodes, electrodes should be higher than 0 ℃) External dimensions: 158 width x 158 height x 170 depth mm Hole size: 140mm x 140mm Weight: 2 kilograms --------------------------------------------------------------------------------------------------------------------------------------------------The electrode structure is sturdy and has strong anti pollution ability. Two relays can achieve high/low temperature or oxygen concent

1. Instrument features
1. The instrument uses high-performance integrated circuits to form a stable sine wave generator, resulting in stable display and small drift;
2、 The instrument adopts a phase sensitive detector to suppress the influence of distributed capacitance from electrode leads on measurement. Therefore, this instrument does not require a capacitance compensation regulator, and can automatically compensate for gear shifting and measure low conductivity values;
3、 Synchronized switching of instrument signal so